Azzota® Portable Conductivity/TDS Meter (2020 Model)
AzzotaProfessional portable conductivity meter, 5 points calibration, selectable TDS conversion factor, setup menu contains 10 options, accuracy: 0.5% F.S
Features
- The professional portable conductivity meter is equipped with a backlit LCD display.
- 1 to 5 points calibration with automatic recognition for conductivity standards.
-
Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and pure water compensation modes.
- Automatic temperature compensation ensures accurate readings over the entire range.
- Auto-Read function senses and locks the measurement endpoint.
- Calibration due alarm prompts the user to calibrate the meter regularly.
- Calibration report provides the date and calibration factor.
- Battery indicator shows the remaining battery capacity.
- Auto-Power Off effectively conserves battery life.
- Setup menu allows setting the number of calibration points, stability criteria, temperature unit, date and time, etc.
- Reset function automatically resumes all settings back to the factory defaults.
- Expanded memory stores or recalls up to 500 data sets.
- USB communication interface is easy to transfer data to the PC.
- Multi-mode power scheme (batteries, power adapter, and USB port) ensures that using the meter smoothly.
Packing list
- PCM-530 meter
- CON-1 conductivity electrode (included)
- CON-0.1 and CON-10 conductivity electrode (option)
- TP-10K temperature probe
- Conductivity standards 84µS/cm, 1413µS/cm, 12.88mS/cm
- Carrying case
Specifications
Model |
PCM-530 |
Conductivity |
|
Range |
0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Accuracy |
±0.5% F.S |
Resolution |
0.001, 0.01, 0.1, 1, automatic |
Calibration Points |
1 to 5 points |
Calibration Solutions |
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
TDS |
|
Range |
0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt) |
Accuracy |
±1% F.S |
Resolution |
0.01, 0.1, 1, automatic |
TDS Factor |
0.1~1.0 (Default 0.5) |
Temperature |
|
Range |
0~105°C, 32~221°F |
Accuracy |
±0.5°C, ±0.9°F |
Resolution |
0.1°C, 0.1°F |
Offset Calibration |
1 point |
Calibration Range |
Measured value ±10°C |
General |
|
Temperature Compensation |
0~100°C, 32~212°F, manual or automatic |
Temperature Coefficient |
0.0~10.0%/°C |
Compensation Mode |
Linear or pure water |
Cell Constant |
K=0.1, 1, 10 or custom |
Reference Temperature |
20°C or 25°C |
Stability Criteria |
Low or high |
Calibration Due Alarm |
1 to 31 days or off |
Memory |
Stores up to 500 data sets |
Output |
USB communication interface |
Connector |
6-pin DIN |
Display |
3.5" custom LCD |
Power |
3×1.5V AA batteries or DC5V power adapter |
Battery Life |
Approximately 150 hours (Turn off the backlit) |
Auto-Power Off |
10, 20 or 30 minutes after last key pressed |
Dimensions |
170(L)×85(W)×30(H)mm |
Weight |
11 oz |