Azzota® Benchtop Advanced pH/ORP Meter (A120 Model)
AzzotaProfessional benchtop pH meter, 7 inch TFT display, stores up to 1000 data sets, setup menu contains 17 options, accuracy: 0.002pH.
Features
- Auto-Read function senses and locks the measurement endpoint.
- Timed Interval Readings send the measurement data to a PC or printer.
- Limit Alarm automatically alerts when reading exceeds the specified range.
- Calibration due to the alarm prompts users to calibrate the meter regularly.
- The calibration report shows the date, time, pH slope, and offset.
- Password protection prevents unauthorized calibration and settings.
- Expanded memory stores or recalls up to 1000 data sets.
- The reset function automatically resumes all settings back to the factory defaults.
- Can use external Printer for date print
PH Mode
- A professional benchtop pH meter is equipped with a 7-inch TFT display.
- 1 to 5 points calibration with automatic recognition for USA, NIST, and DIN buffers.
- Automatic temperature compensation ensures accurate readings over the entire range.
- The solution temperature coefficient compensates for the pure water samples and references the pH to 25°C.
ORP Mode
- 1-point offset calibration allows adjusting the displayed value to a known standard.
-
Relative and absolute millivolt modes ensure reliable ORP measurements.
Packing list
- PHORP-A120 Meter
- E201-BNC pH electrode
- TP-10K temperature probe
- pH4.01/7.00/10.01 buffer
- DC12V power adapter
Specifications
Model |
PHORP-A120 |
|
pH |
||
Range |
-2.000 to 20.000pH |
|
Resolution |
0.001, 0.01pH, selectable |
|
Accuracy |
±0.002pH |
|
Calibration Points |
1 to 5 points |
|
pH Buffer Options |
USA, NIST, DIN, 5 custom buffers |
|
ORP |
||
Range |
±2000.0mV |
|
Resolution |
0.1mV |
|
Accuracy |
±0.2mV |
|
Calibration Points |
1 point |
|
Measurement Modes |
Relative or absolute mV |
|
Temperature |
||
Range |
0 to 105°C/32 to 221°F |
|
Resolution |
0.1°C/0.1°F |
|
Accuracy |
±0.5°C/±0.9°F |
|
Offset Calibration |
1 point |
|
Calibration Range |
Reading ±10°C |
|
General Specifications |
||
Temperature Compensation |
0 to 100°C/32 to 212°F, manual or automatic |
|
Stability Criteria |
|
Standard or high-accuracy |
Calibration Due Alarm |
|
1 to 31 days or off |
Interval Readings |
|
10, 30, 60 seconds, 10, 30 minutes or off |
Password Protection |
|
4 digits |
Memory |
|
Stores up to 1000 data sets |
Output |
|
USB communication interface |
Connector |
|
BNC, 3.5mm jack socket |
Display |
|
7” TFT LCD |
Power |
|
DC12V, using AC adapter |
Dimensions |
|
240(L)×220(W)×80(H)mm |
Weight |
|
4 lbs |